Successful Installation of Stand Alone Screen in Challenging Environment in Umm Niqa Field

Zeidan, Amr, Al-Bader, Haifa, Pandey, H Chandra, Al-Ibrahim, Abdullah, Ayyavoo, Mani, Al-Ateeq, Abdullah, AL-Kandary, Esraa, Erhamah, Abdulaziz, Bosilca, Daniel

OnePetro 

Abstract Objectives/Scope

In 2014, number of exploratory wells were drilled and tested in Umm Niqa (UN) Field located in north Kuwait NE which approved a new discovery in Lower Fars (LF) reservoir.

LF is unconsolidated, sub –hydrostatic- sand stone reservoir with highly sour and moderate corrosive environment (H2S 8% and CO2 4%). Subsequently additional wells were drilled to evaluate the production potential of UN field. With rig on location UN wells are completed with test (Progressive Cavity Pump) PCP and tested. During the initial testing period the PCP is run at different speeds to evaluate the well productivity, water cut, and determine sand-free draw down to enable selection of suitable completion PCP for production.

Methods, Procedures, Process

Well UN-X is one of the developed wells which is perforated in LF sand in overbalanced condition using 4-1/2" (High Shot Density) HSD guns with 0.83" entrance hole diameter at 12 shoots per foot.

During initial testing with test PCP, the pump tripped due to high torque because of sand production (up to 60%). Five runs were performed to clean out the wellbore and repeated test PCP runs failed due to high sand production.

Coordination between FDHO (Field Development Heavy Oil) and Discovery Promotion Team was conducted to perform quick sand analysis to LF sands from offset sand distribution since subject well has no available sieve analysis. Based on the outcome of sieve analysis, decision was made to utilize one of the available SAS (Stand Alone Screen) designed for LF sand in another field to control sand production. It was agreed by both teams to install SAS in the subject well to mitigate the sand problem and minimize cost due to NPT (Non-Productive Time) of the rig. SAS was installed and the potential zone in UN-X could be tested successfully with tubing PCP. No sand problem was observed during testing and after testing while clean out operation there was no sand.

Results, Observations, Conclusions

Well test showed an average liquid rate of 124 BFPD with 37% WC (predominantly completion brine). The well was put on production on November 2016 and producing till date without any sand problem.

Novel/Additive Information

This paper will include discussion on the approach used to select a sand control method for cold and heavy oil production. The results of sieve analysis was in the middle between sand screen and gravel pack but based on the team experience in sand control and the nature of heavy oil and its relatively low oil production rate, the decision was made to install SAS and that was proved to be prudent decision.